Even a lot of companies in China supply the Temporary fence to Australia but most of them have no idea about AS 4687
APAC has enough knowledge of this standard and APAC's fence is strictly conforms to it.
1. Simulated Climbing Test
APAC fence panel can successfully support a 65kg test load without overturning.
2. Impact Test
APAC single fence panel assembled with the addition of a single, interlocking back brace can bear an impact collision of 150 joules, without visible sign of cracking, no overturning and the dynamic deflection is less than 300mm.
3. Infill Aperture Test
3.1 The infill aperture horizontal width was measured to be 60mm, less than the specified maximum of 75mm. A test block measuring 76mm x 76mm could not be passed through the rectangular-shaped mesh infill.
3.2 Infill downward load test resulted in a deflection of 5mm, less than the specified permissible maximum of 35mm.
4. Wind Force Overturning Test
4.1 A APAC Temporary Fence panel fitted with footings, one interlocking back brace and a single foot block can bear the wind speed of 24m/s, meets the minimum wind speed requirement for Region A-D (AS 4687-2007)
4.2 Two (2) APAC Temporary Fence panels fitted with footings, one interlocking back brace, and one-foot block can bear a wind speed of 18m/s, meet the minimum wind speed requirement for Region A-B.
4.3 Two (2) APAC Temporary Fence panels fitted with footings, one interlocking back brace, and two-foot blocks can bear a wind speed of 24m/s, meet the minimum wind speed requirement for Region A-D.